Table 21: Programmable I/O Status Labels (Read Only)
1
Label
2
Data Type Function
AARMED[1-8]
ACCAREA.0-7
ACHIME[1-8]
ACODE2[1-8]
AENTRY[1-8]
AEXIT[1-8]
AINST[1-9]
ALMAREA.0-7
BIT
BIT
BIT
BIT
BIT
BIT
BIT
BITS
Area[n] armed
Area last accessed for door
Area[n] in Chime Mode
Area[n] in Code2 Mode
Area[n] in entry delay
Area[n] in exit delay
Area[n] in Instant Mode
Areas in alarm
ALMTYP
AREADY[1-8]
ATROUBL[1-8]
AUDALM.0-7
AUDAREA.0-7
AUXALM
AUXRLY.0-7
AZONES[1-10]
NUMBER
BIT
BIT
BIT
BITS
BIT
BITS
BITS
Current alarm type
Area[n] ready
Area[n] zone trouble
Areas with any not silent alarm
Areas using audio
Auxiliary alarm type
Aux. control relay status
Zones that are armed
ABYPASS[1-8]
BYPASS
CENT
CHIMEON
DACT
DOOR80
DOOROPEN[0-15]
DOORRLY[0-15]
DOORBSUPR[0-15]
BIT
BIT
NUMBER
BIT
BIT
BITS
BIT
BIT
BIT
Area[n] has bypassed zones(s)
Zones bypassed in system
Century
Chime tone on
Dialer active
Toggled by pressing 16-23 Door
Door is open
Door relay control
Touchpad door trouble
DOORBYPS[0-15]
DURESS
EMER
EXTBELL
EXEC
FIRE
HLDAY
HZNC[1-10]
HDEBO[1-10]
BIT
BIT
BIT
BIT
BIT
BIT
BIT
BITS
BITS
Door relay bypass
Duress alarm
Emergency alarm
External bell output
IF Controls Program
Fire alarm
Holiday
Zone inputs above high limit
Debounced zone inputs high
ICALL
ICOM
INTRU
INTBELL
IRDY
ITR
IZONES[1-10]
NUMBER
BIT
BIT
BIT
BIT
BIT
BITS
Station number for intercom call
Intercom active
Intrusion alarm
Internal bell output on
Zones all ready
Zone in trouble
Zones that are interior bypassed
KEYSUPR[0-15]
LISTEN
LOWBAT[1-10]
LZNC[1-10]
LDEBO[1-10]
MDAY
MONTH
BIT
BIT
BITS
BITS
BITS
NUMBER
NUMBER
Touchpad supervise trouble
Listen-in active
Zones with low battery
Zone inputs below limit
Debounced zones below limit
Day of month
Month
ORGKID
P1SEC
P500MS
PAPOUT
PASS1
PASS10
NUMBER
BIT
BIT
BIT
BIT
BIT
Touchpad using phone/intercom
Pulse at one per second
Pulse at two per second
Printer paper out
True for one pass of I/O prog. each second.
True for one pass of I/O prog. every 10 second.
PASS60
PHONE
READY
REPORT
SILENC
SMKPWR
SPECL
SYSTR
BIT
BIT
BIT
BIT
BIT
BIT
BIT
BIT
True for one pass of I/O prog. each minute
Phone mode active
Zones ready
Dialer reporting
Trouble silenced
Smoke power on
Special alarm
System trouble
NOTE
1
A status condition can only be read (on the right side of statement), so that the information
can be used to determine whether or not an output will be generated. Status conditions cannot
be altered by programmable I/O statements.
2
In this column, the number in brackets [ ] indicates how many devices or components of this
type are available