BELL TST PU:NO (bell test at power-up)
This option causes the system to sound a two-second bell test whenever the system is reset.
DIALER:YES
The dialer must always be selected for normal operation. It can be disabled for troubleshooting
or while training end users. When the dialer is disabled, there is no battery or AC detection.
PRINTER:NO
Select this option if you are using a Model 5260 Printer Interface.
ZONE EXP1:NO
If at least one zone expander is to be used with the system, this option must be selected.
ZONE EXP2:NO
If two zone expanders are to be used with the system, both ZONE EXP1 and ZONE EXP2
must be selected.
INTERCOM:NO
Select this option if you are using the Model 4140 Intercom Module.
AUX CONTROL:NO
Select this option if you are using the Model 4150 Auxiliary Control Module.
INTERN ZONES:16
Select the number of internal zones used (zones built into the 4720 panel). This will let the sys-
tem know where to start the expansion zones.
EXP ZONES#1:0
Enter the number of zones on Expander #1.
RESD CODE#1:0123
Select the residence code to be used with RF Zone Expander #1. This code must be the same as
the residence code programmed into the transmitters; see the section on expansion zones in the
4720 Installation Manual (P/N 150476). Skip this step if NOT using an RF zone expander.
Table 6: Default Mode Selections
Selection Default Mode
0
The system will default to the DISARMED mode and will NOT generate an
Open Report to the central station.
1
The system will default to the DISARMED mode and WILL generate an Open
Report.
2
The system will default to the ARMED mode and will automatically bypass
(shunt) any zones that are not ready to be armed. The system will also gener-
ate a Close Report.
3
The system will default to the ARMED Mode. If any zones are not ready to be
armed, they will go into the ALARM condition and the appropriate report will be
sent to the central station. If all of the zones are ready, only a Close Report will
be generated.