LISTINGS AND CODE APPROVALS
These gas appliances have been tested in
accordance with AS4553-2000, NZS 5262
and have been certi ed by the Australian
Gas Association for installation and opera-
tion as described in these Installation and
Operating Instructions.
Your unit should be serviced annually by
an authorised service person.
918-448d
IG35 Gas Inbuilt
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appli-
ance
Do not touch any electri-
cal switch: do not use any
phone in your building.
Immediately call your gas
supplier from a neighbour's
phone. Follow the gas sup-
plier's instructions.
If you cannot reach your
gas supplier, call the re
department.
WARNING:
Improper installation, adjustment, altera-
tion, service or maintenance can cause
injury or property damage. Refer to this
manual. For assistance or additional in-
formation consult an authorised installer,
service agency or the gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other am-
mable vapours and liquids in the vicinity of
this or any other appliance.
Installation and service must be performed
by an authorised installer, service agency or
the gas supplier.
Vista de página 0
1 2 3 4 5 6 ... 31 32

Resumo do Conteúdo

Página 1 - IG35 Gas Inbuilt

PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCEModels: IG35-NG IG35-LPG IG35-ULPGOwners &Installation Manual01/06/14LISTINGS AND CODE APPROV

Página 2 - UNIT DIMENSIONS

10Regency IG35 Gas Inbuilt Fireplace16) Turn on gas supply and plug in power cord.Installer Notice: These instructions must be left with the appliance

Página 3 - TABLE OF CONTENTS

11Regency IG35 Gas Inbuilt FireplaceConversion Kit #486-967 for NG to ULPGTHIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOU

Página 4 - DATA BADGE

12Regency IG35 Gas Inbuilt Fireplace16) Turn on gas supply and plug in power cord.Installer Notice: These instructions must be left with the appliance

Página 5

13Regency IG35 Gas Inbuilt FireplaceThe "02" refer numbers (i.e. 02-65) are molded into the rear of each log.1) Carefully remove the logs f

Página 6

14Regency IG35 Gas Inbuilt FireplaceNotchE)02-45BracketA)02-65The bottom right edge of Log G)02-48 must sit snugly against the bracketSide ViewG)02-48

Página 7

15Regency IG35 Gas Inbuilt FireplaceDiagram 1FACEPLATE, TRIM & LOUVER INSTALLATION1) Lay the faceplate panels fl at, face down on something soft s

Página 8

16Regency IG35 Gas Inbuilt FireplacePREMIUM FLUSH FRONT INSTALLATION6) Place the ECS manual control switch key pad on the outside of the opening in t

Página 9

17Regency IG35 Gas Inbuilt Fireplace11) Place the cable ties thru the cable tie holders in the heat shield loosely to secure loose wires. Run the CA

Página 10 - INSTALLATION

18Regency IG35 Gas Inbuilt FireplaceHeat Defl ectorTab into Tab BracketDiagram 1115) Completely mount the faceplate to the unit. .See diagram 13.Diagra

Página 11

19Regency IG35 Gas Inbuilt Fireplace19) Carefully lift off the ignition module from the velcro and slightly bring forward. Remove the wire harness con

Página 12

2Regency IG35 Gas Inbuilt FireplaceREGENCYGAS INBUILT FIREPLACETO THE NEW OWNERCongratulations! You are the owner of a state-of-the-art Gas Inbuilt F

Página 13

20Regency IG35 Gas Inbuilt Fireplace25) Secure all loose wires in the wire clip to the right side of the valve. See diagram 23.Diagram 2326) Secure th

Página 14

21Regency IG35 Gas Inbuilt FireplaceREMOTE CONTROL Use the Regency Remote Control Kit approved for this unit. Use of other systems may void your warr

Página 15

22Regency IG35 Gas Inbuilt FireplaceWIRING WITH PREMIUM FLUSH FRONT OPTIONCAUTION: Label all wires prior to disconnection when servicing controls. W

Página 16

23Regency IG35 Gas Inbuilt FireplaceOPERATING INSTRUCTIONSOPERATING INSTRUCTIONS Before operating this appliance, proceed through the following check

Página 17

24Regency IG35 Gas Inbuilt FireplaceCOPY OF LIGHTING INSTRUCTION PLATEOPERATING INSTRUCTIONSNORMAL OPERATING SOUNDS OF GAS APPLIANCESIt is possible th

Página 18

25Regency IG35 Gas Inbuilt FireplaceMAINTENANCECAUTION: ANY SAFETY SCREEN OR GUARD REMOVED FOR SERV-ICING AN APPLIANCE MUST BE REPLACED PRIOR TO OPER

Página 19

26Regency IG35 Gas Inbuilt FireplaceMAINTENANCEFAN MAINTENANCETo Remove Fan:1) Turn the unit off and allow it to cool to room temperature,2) Unplug

Página 20

27Regency IG35 Gas Inbuilt FireplaceMAINTENANCEREMOVINGVALVE TRAY1) Unplug or disconnect the power source to the stove. 2) Shut off the gas supply a

Página 21

28Regency IG35 Gas Inbuilt FireplacePARTS LISTELECTRONIC COMPONENTS PARTS LIST910-936910-082910-088910-089910-084910-527910-935910-080910-521, 910-522

Página 22

29Regency IG35 Gas Inbuilt FireplaceMAIN ASSEMBLY Part # Description Part # Description1) 910-169/P F

Página 23 - OPERATING INSTRUCTIONS

3Regency IG35 Gas Inbuilt FireplaceTABLE OF CONTENTSREGENCY GAS FIREPLACE INSERTDATA BADGEData Badge...

Página 24

30Regency IG35 Gas Inbuilt FireplacePARTS LISTFACEPLATE ASSEMBLY Part # Description Part # Descriptio

Página 25 - MAINTENANCE

31Regency IG35 Gas Inbuilt FireplaceWARRANTYExclusions:This limited Lifetime Warranty does not extend to or include paint, door or glass gasketing or

Página 26

Printed in Canada© Copyright 2014, FPI Fireplace Products International Ltd. All rights reserved.Installer: Please complete the following informationD

Página 27

4Regency IG35 Gas Inbuilt FireplaceDATA BADGE(Australia Only)This is a copy of the label that accompanies each Regency IG35 Gas Inbuilt fi replace. We

Página 28 - PARTS LIST

5Regency IG35 Gas Inbuilt FireplaceINSTALLATIONIMPORTANT MESSAGEThe Regency Gas Fireplace must be installed in accordance with these instructions. Car

Página 29

6Regency IG35 Gas Inbuilt FireplaceINSTALLATIONGAS CONNECTION 3) Locate the center point where the fl ue will pass through the chimney above the appli

Página 30

7Regency IG35 Gas Inbuilt FireplaceINSTALLATION FLUEINGTHE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL BURNING APP

Página 31 - WARRANTY

8Regency IG35 Gas Inbuilt FireplaceTEST FOR FLUE SPILLAGEA " spillage" test must be made before the installed unit is left with the customer

Página 32 - warranty online

9Regency IG35 Gas Inbuilt FireplaceINSTALLATION Conversion Kit #486-968 for NG to LPG ModelTHIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FI