Regency P33-NG4 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Lareiras Regency P33-NG4. Regency P33-NG4 User's Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 52
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
918-520
MODELS: P33-NG4 Natural Gas P33-LP4 Propane
P33-4 Zero Clearance
Direct Vent Gas Fireplace
06/08/06
Owners &
Installation Manual
WARNING:
If the information in these instructions are not followed exactly,
a fi re or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualifi ed
installer, service agency or the gas supplier.
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fi re department.
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
www.regency-fi re.com
Vista de página 0
1 2 3 4 5 6 ... 51 52

Resumo do Conteúdo

Página 1 - Installation Manual

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4918-520MODELS: P33-NG4 Natural Gas P33-LP4 PropaneP33-

Página 2

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace10The Top Facing Support, the Side Nailing Strips and the 2 Top Standoffs must be correctly pos

Página 3 - TABLE OF CONTENTS

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace11EXTERIOR VENT TERMINATION LOCATIONSINSTALLATIONA= Clearance above grade, veranda, porch, dec

Página 4 - SAFETY LABEL

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace12IMPORTANTIf using any Cabinet Mantels with Part # 510956, 510958, 510962, 510964 and 510834 t

Página 5 - REQUIREMENTS

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace13Termination CapWall Thimble 2 pieces(10" (254mm) Outer Diameter)2”x4”or2”x6”(21mm x 102m

Página 6

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace14PipeLengthVerticalTerminalStormCollarFlashingCeilingFirestop24"LengthAdj.PipeLength

Página 7

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace15FPI946-506/P Vent Guard (Optional)510-994 Rigid Pipe Adaptor (Must use with all Rigid Piping

Página 8

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace16INSTALLATION• Vent must be supported at offsets.• Firestops are required at each fl oor le

Página 9

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace17The P33-4 is approved for a maximum 40 ft. straight vertical, with rigid pipe vent systems fo

Página 10 - INSTALLATION

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace18RIGID PIPE VENTING ARRANGEMENTS Horizontal TerminationsREGENCY® DIRECT VENT SYSTEM (FLEX)(Pr

Página 11

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace19Horizontal Venting with Two (2) 90o ElbowsHorizontal Venting with Two (2) 90o ElbowsHorizonta

Página 12

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace2To the New Owner:Congratulations! You are the owner of a state-of-the-art Gas Fireplace by FP

Página 13

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace20Horizontal Venting with Three (3) 90o ElbowsVertical Venting with Two (2) 90o ElbowsVertical

Página 14

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace21INSTALLATIONVertical Venting with Three (3) 90o ElbowsVertical Venting with Three (3) 90o Elb

Página 15

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace22FlexLinerExhaustFlueA maximumoftwocertifiedjoinerkitsmaybeusedperlength.#948-30535ft

Página 16

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace23VENTING ARRANGEMENTS - VERTICAL TERMINATIONS with Co-linear Flex System for bothResidential &

Página 17

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace24Riser VentTerminationMin. 6-1/4"*(159mm)INSTALLATIONDiagram 3UNIT INSTALLATION WITH HORI

Página 18

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace25INSTALLATIONGAS LINE INSTALLATIONThe gas line is brought through the right side of the applia

Página 19

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace26GAS PIPE PRESSURE TESTINGThe appliance must be isolated from the gas supply piping system by

Página 20

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace27INSTALLATIONEach Kit contains one LPG Conversion Kit and one DCSparker Kit.LPG Conversion Kit

Página 21

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace28INSTALLATIONWARNING!Do not overtighten the screw. Recommended to gripthe wrench by the short

Página 22

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace29INSTALLATION4) Install the 3/4" nylon plug to cover up the hole on the mounting bracket

Página 23

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace3TABLE OF CONTENTSFull Screen doors ...34Op

Página 24

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace30Note: The logs must not be in the unit.3) Insert the back brick panel by carefully slipping

Página 25

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace31Diagram 1Diagram 3STANDARD FLUSH DOORThe standard fl ush door comes with a black frame. To ins

Página 26

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace32OPTIONAL BAY DOORThe Bay louvers MUST be usedwith the Bay glass option.The optional Bay door

Página 27

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace336) Open the bottom louver. Pull the Burner ON/OFF control box from inside the bottom of the

Página 28

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace34FULL SCREEN DOORS1) Before beginning the installation, remove the Glass Door from the unit.

Página 29

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace356) Place the Bottom Frame near the hinges, and fl ip down the hinges from the Bottom Face Pla

Página 30

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace36Optional WALL SWITCH1) Run the supplied 15' of wire through the right or left side gas

Página 31

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace37WIRING DIAGRAMS This heater does not require a 120V A.C. supply for operation. In case of a p

Página 32

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace38Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges.CA

Página 33

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace39INSTALLING THE OPTIONAL FAN120 Volt AC power is needed for the fan switch and blower. The fan

Página 34

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace4SAFETY LABELThis is a copy of the label that accompanies each P33-4 Zero Clearance Direct Vent

Página 35

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace40OPERATING INSTRUCTIONSCOPY OF THE LIGHTING PLATE INSTRUCTIONSGas InletOFFGas Inlet

Página 36

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace41AERATION ADJUSTMENTThe air shutter can be adjusted by moving the adjusting wire up or down. T

Página 37

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace42MAINTENANCEMAINTENANCE INSTRUCTIONS1) Always turn off the gas valve before cleaning. For rel

Página 38

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace43MAINTENANCETHERMOPILE/THERMOCOUPLE1) Open the bottom louvers.2) Loosen the thermocouple or

Página 39

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace44REMOVING VALVE1) Shut off the gas supply.2) Remove the louvers (and bay door if it is on).3

Página 40 - OPERATING INSTRUCTIONS

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace45PARTS LISTMAIN ASSEMBLY Part # Description Part # Description

Página 41

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace46PARTS LIST

Página 42 - MAINTENANCE

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace47BURNER & LOG ASSEMBLY Part Description 53) 430-055 Ga

Página 43

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace48PARTS LISTFLUSH FRONT & LOUVERS Part # Description Part #

Página 44

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace49111117 123117 1231251261201201071201081071201201201201201071201201061201061201201201291291181

Página 45 - PARTS LIST

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace5REQUIREMENTS 5.08: Modifications to NFPA-54, Chapter 10(2) Revise 10.8.3 by adding the followi

Página 46

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace50NOTES________________________________________________________________________________________

Página 47

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace51WARRANTYRegency® Fireplace Products are designed with reliability and simplicity in mind. In

Página 48

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace52Installer: Please complete the following informationDealer Name & Address: ______________

Página 49

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace6INSTALLATIONIMPORTANT MESSAGE SAVE THESE INSTRUCTIONSThe P33-NG4 or P33-LP4 Direct Vent Firep

Página 50

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace7DUCT SYSTEM OPTIONkit #946-556The HeatWave Air Duct Kit increases the effectiveness of your fi

Página 51 - WARRANTY

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace8COMBUSTIBLE MANTELSBecause of the extreme heat this fi replace emits, the mantel clearances are

Página 52

Regency® P33-4 Zero Clearance Direct Vent Gas Fireplace9INSTALLATION3) For exterior walls, insulate the enclosure to the same degree as the rest of t

Comentários a estes Manuais

Sem comentários